Skip to content
InjectBuddy
Skip to main content

BPC-157 + TB-500 blend vials mg/mL and U-100 units, worked through

See the draw for a blend

Open calculator

Last updated:

A BPC-157 + TB-500 blend vial holds both peptides in one vial, so its concentration is the total blend mg divided by the BAC water added: a 10 mg (5/5) blend in 2 mL is 5 mg/mL, and each 0.1 mL (10 units on a U-100 syringe) holds 0.5 mg of blend, split 0.25 mg of each peptide. Units = (mg ÷ mg/mL) × 100. This guide shows the maths, the vial types and a chart; it does not set an amount for anyone.

Key takeaways: A blend vial fixes the BPC-157:TB-500 ratio for you, so the maths collapses to a single concentration. Total blend mg ÷ BAC water mL = mg/mL. Dose ÷ mg/mL × 100 = units. Both peptides are preclinical — this is a maths reference, not a dosing recommendation.

This guide explains the two vial types, works through the three-step formula with a chart and worked examples, and answers the questions people ask most.

What a BPC-157 + TB-500 blend vial is

Many research suppliers sell BPC-157 and TB-500 pre-combined in one lyophilized vial at a fixed ratio — commonly labeled by total milligrams and ratio, such as a 10 mg blend at 5 mg BPC-157 / 5 mg TB-500, or an 11 mg blend at 5 mg / 6 mg. Because both peptides share the same vial and the same water, you reconstitute and draw once, not twice. That is the whole appeal: one calculation, one injection.

The trade-off is that the ratio is locked at the factory. With separate vials you can dial any BPC-157:TB-500 split you like; with a blend you take whatever ratio the label states. So the first thing to read off the vial is the total mg — that is the number your concentration maths uses.

Vial types: one blend vial or two separate vials

The word “blend” can describe two different setups. A dual-peptide vial contains both BPC-157 and TB-500 in the same container, at a fixed ratio. Add water once, calculate from the total powder mass, and make one draw.

Two separate vials contain one peptide each. Each vial has its own concentration, so calculate each draw independently and combine the volumes in the syringe. The two setups are not interchangeable: a single-vial calculation does not describe two vials, and two separate-vial calculations do not describe a fixed-ratio blend.

Separate vials let you choose the amount of each peptide independently. A dual vial ties the amounts together according to its label ratio. For example, if the label lists equal amounts, each draw contains equal amounts; with an unequal ratio, a single draw cannot change that proportion.

Read the amount of each peptide on the label rather than assuming that every product called a blend is 1:1.

For two vials, use the concentration printed or calculated for each vial, then apply the desired dose for that peptide. Add the two resulting volumes to find the total syringe fill.

If both vials have the same concentration and the doses are equal, both draws use the same number of units. If their concentrations differ, the unit marks differ too.

The blend calculator models two independent vial inputs, so use it for separate vials; use the total mass and fixed ratio when reasoning about a dual vial.

How the maths works

A blend vial behaves like any single peptide vial, except the "peptide content" is the sum of both peptides:

The three-step blend formula

1. Blend concentration (mg/mL) = Total blend mg ÷ BAC water added (mL)

2. Draw volume (mL) = Your dose (mg) ÷ Blend concentration (mg/mL)

3. Units on a U-100 syringe = Draw volume (mL) × 100

Because the ratio is fixed, one dose figure covers both peptides at once.

The subtlety: when you draw a "1 mg blend dose" from a 5 mg / 5 mg vial, you are taking 0.5 mg BPC-157 and 0.5 mg TB-500 in that single draw — the ratio rides along automatically.

If the label is 5 mg / 6 mg (11 mg total), the same 1 mg draw delivers roughly 0.45 mg BPC-157 and 0.55 mg TB-500. The syringe units only ever track the total concentration.

When two separate vials have different concentrations

Do not double one draw when the vials are mismatched. Work out each concentration and each volume on its own, then add the volumes. For example, a 5 mg BPC-157 vial mixed with 2 mL contains 2,500 mcg/mL; 250 mcg corresponds to 0.10 mL, or 10 units.

A 10 mg TB-500 vial mixed with 5 mL contains 2,000 mcg/mL; 250 mcg corresponds to 0.125 mL, or 12.5 units. Exact arithmetic gives 0.225 mL, or 22.5 unit-equivalents.

The calculator rounds each vial's unit display to a whole number, so it shows 10 + 13 = 23 units and a total volume of 0.23 mL. Enter each vial strength and water amount with a 250 mcg dose to check the same inputs.

The combined volume determines whether the draw fits your syringe, while each individual draw determines where to stop before switching vials. A combined total that fits the barrel may still include a fractional unit mark.

Check the barrel capacity and graduations before drawing; do not round away a difference between the two concentrations.

Blend vial chart: mg to mg/mL to units

This chart reconstitutes whole blend vials with 2 mL of bacteriostatic water and shows the units for a 1 mg total-blend dose. Halve the dose, halve the units.

Blend vial (total mg)BAC waterConcentration1 mg dose drawUnits (U-100)
5 mg (2.5/2.5)2 mL2.5 mg/mL0.40 mL40 units
10 mg (5/5)2 mL5 mg/mL0.20 mL20 units
11 mg (5/6)2 mL5.5 mg/mL0.18 mL18 units
15 mg (7.5/7.5)2 mL7.5 mg/mL0.13 mL13 units
20 mg (10/10)2 mL10 mg/mL0.10 mL10 units
BPC-157 + TB-500 blend vial concentration and syringe draw A 10 mg blend vial reconstituted with 2 mL of bacteriostatic water gives 5 mg/mL; a 1 mg dose is 0.2 mL, which is 20 units on a U-100 insulin syringe. 10 mg blend + 2 mL BAC → 5 mg/mL concentration 0 50 100 20 units 1 mg dose = 0.2 mL = 20 units
A 10 mg (5/5) blend vial with 2 mL water reads 5 mg/mL; a 1 mg blend dose draws to the 20-unit mark.

Reconstitution steps

  1. Read the total mg and ratio off the label (e.g. "10 mg · 5/5"). The total mg is what your maths uses.
  2. Wipe the septum with an alcohol swab; let it dry 10–15 seconds.
  3. Draw your chosen BAC water volume and inject it slowly down the inside wall of the vial. Swirl gently — never shake — until fully dissolved.
  4. The solution should be clear and free of particles, and its color should match what is normal for that product. Discard if cloudy, if particles persist, or if it has darkened or changed color.
  5. Label the vial with the concentration and reconstitution date, then refrigerate.

Less water means a higher mg/mL and fewer units per dose; more water means a lower mg/mL and more units. Choosing the water volume so a typical dose lands between 10 and 40 units keeps the draw easy to read.

Got a blend vial? See the draw for your numbers Take your time. Nothing here asks you to start.

Open calculator

Storage

A blend vial follows the same storage rules as any lyophilised peptide vial, because the label, not the ratio, sets them. Before mixing, the dry powder is stored as the supplier’s label states, usually refrigerated at 2–8 °C and away from light. Once bacteriostatic water goes in, the vial becomes a multi-dose solution: keep it in the fridge, never in the freezer, and write the mixing date and a discard date on the label.

The discard date is simple date maths: add the in-use days to the mixing date. With the 28-day in-use guide that USP <797> and the CDC apply to an entered multi-dose vial, a vial mixed on 1 March is discarded on 29 March, or on the printed expiry if that is earlier. A shorter window on the supplier’s sheet always wins. The peptide storage and discard dates guide works through more dates, and the medication storage calculator guide shows the same sum for any product.

Storage never changes the maths above. A vial mixed with 2 mL still holds the same total mg on day 1 and day 20; only the discard date limits how many draws you can take from it.

Worked examples

10 mg blend, 2 mL water, 1 mg dose

10 mg ÷ 2 mL = 5 mg/mL. Draw = 1 ÷ 5 = 0.20 mL.

0.20 mL = 20 units
10 mg blend, 2 mL water, 0.5 mg dose

Concentration still 5 mg/mL. Draw = 0.5 ÷ 5 = 0.10 mL.

0.10 mL = 10 units
20 mg blend (10/10), 3 mL water, 1 mg dose

20 mg ÷ 3 mL = 6.67 mg/mL. Draw = 1 ÷ 6.67 = 0.15 mL.

0.15 mL = 15 units
11 mg blend (5/6), 2 mL water, 1 mg dose

11 mg ÷ 2 mL = 5.5 mg/mL. Draw = 1 ÷ 5.5 = 0.182 mL.

That 1 mg draw is ~0.45 mg BPC-157 + ~0.55 mg TB-500 (the 5:6 ratio).

0.182 mL ≈ 18 units
5 mg blend (2.5/2.5), 1 mL water, 0.5 mg dose

5 mg ÷ 1 mL = 5 mg/mL. Draw = 0.5 ÷ 5 = 0.10 mL.

0.10 mL = 10 units
15 mg blend (7.5/7.5), 2 mL water, 1.5 mg dose

15 mg ÷ 2 mL = 7.5 mg/mL. Draw = 1.5 ÷ 7.5 = 0.20 mL.

0.20 mL = 20 units
Over-1-mL check: 10 mg blend, 5 mL water, 2 mg dose

10 mg ÷ 5 mL = 2 mg/mL. Draw = 2 ÷ 2 = 1.00 mL — exactly fills a 1 mL insulin syringe.

1.00 mL = 100 units (use less water to shrink this draw)

So, how does the blend vial maths work?

Divide the total blend mg by the volume of bacteriostatic water you add to get mg/mL, then divide your dose by that concentration and multiply by 100 to read the units on a U-100 insulin syringe.

For a common 10 mg (5/5) vial reconstituted with 2 mL, a 1 mg dose is 5 mg/mL concentration, 0.20 mL, and 20 units. Use the BPC-157 + TB-500 blend calculator to enter your exact vial, water volume, and dose and get the draw instantly.

Frequently asked questions

How do you work out units from a BPC-157 + TB-500 blend vial?
Divide the total blend mg by the volume of bacteriostatic water added to get mg/mL, then divide your dose (mg) by that concentration and multiply by 100 to get U-100 syringe units. For a 10 mg (5/5) vial with 2 mL water, a 1 mg dose is 0.20 mL, which is 20 units.
Do I add the two peptides together when calculating concentration?
Yes. In a blend vial both peptides dissolve in the same water, so the concentration that drives your syringe units is the total mg divided by the water volume. A 5 mg / 5 mg vial is a 10 mg blend; with 2 mL water that is 5 mg/mL. You do not calculate each peptide separately — the fixed ratio is already baked into the powder.
How is a blend vial different from using two separate vials?
With two separate vials each has its own concentration, so you calculate two draw volumes and add them in the syringe — and you can pick any ratio. A blend vial fixes the ratio at the factory and collapses everything to one concentration and one draw. The blend is simpler to dose but less flexible; separate vials are more flexible but need two calculations.
What ratio is in a typical BPC-157 + TB-500 blend?
There is no standardised ratio — it is whatever the supplier chose. Common labels are 1:1 (e.g. 5 mg / 5 mg) and slightly TB-500-weighted splits like 5 mg / 6 mg. Because both peptides are preclinical, no ratio is clinically validated; the label simply tells you how the total mg is divided so you know what each draw delivers.
What if a dose makes the draw exceed 1 mL?
A U-100 insulin syringe holds 1 mL (100 units). If a draw exceeds that, reconstitute with less water to raise the mg/mL, split the dose across two injections, or use a larger tuberculin syringe. The blend calculator flags draws over 100 units so you can adjust the water volume before mixing.

Sources

BPC-157 and TB-500 are investigational peptides; the evidence below is predominantly preclinical (animal and in-vitro). Neither is FDA-approved, and no human dose for a combined blend is established. The arithmetic here is standard concentration maths, not a clinical protocol.

This guide is a mathematical reference only and does not constitute medical advice. BPC-157 and TB-500 are not approved for human use; consult a qualified clinician before using any injectable.

Related calculators